that uses SCPI, which is the vast majority of box instruments.PXI instruments do not use SCPI.Feel free
2019-08-06 14:23
C code and I'll also need to store a vast amount of data. Please help!
2019-01-16 06:36
数据表中没有,z***d
2021-07-31 14:44
in order to program/develop the thing. I understand Microchip supports a vast amount of devices
2018-10-30 15:18
树莓派3会自动变频,会在1.2Gh和600Mhz转换,如何将cpu频率固定在1.2ghz?
2020-06-09 05:56
虚拟系统原型是什么?虚拟系统原型有什么作用?
2021-04-27 06:41
嗨,所有,如果我声明,那么X将是一个16位内存位置(签名),据我所知。当我把这个值传递给寄存器时,寄存器中的值是多少?Eg:如果x= 0xFAAF;我把这个值传递给AdRESH或其他寄存器,将AdRESH=0xFA或0xAF。我想它将是0xAF。谢谢任何帮助。 以上来自于百度翻译 以下为原文 Hi all, If I am declaringint x;then x will be a 16 bit memory location(signed) as far as I know.When I pass this value to a register, what would be the value in register?Eg:If x = 0xFAAF; and I am passing this value to ADRESH or some other register, will ADRESH =0xFA or 0xAF.I think it will be 0xAF. Thanks for any help.
2019-07-02 09:21
大家好,我想知道这2个定义是否会产生相同的代码W.R.T时间来对它们进行读写操作?我的意思是,这两种结构的汇编指令都是不同的,但在时间尺度上,哪一种更有效,而对它们进行数据读写操作呢?非常感谢您的帮助。 以上来自于百度翻译 以下为原文 Hello everyoneI wonder if these 2 definitions would produce same code w.r.t time it takes to do read write operations on them? I mean that the assembly instructions for both constructs would be different but on the time scale which one of these would be more efficient while data read write operations are carried out on them? union{ unsigned int LUT[256]; struct {unsigned char LUT_L;unsigned char LUT_H; }s_LUT[256]; }u_LUT; Or union{ unsigned int LUT; struct {unsigned char LUT_L;unsigned char LUT_H; }s_LUT; }u_LUT[256]; Your help is highly appreciated.
2018-11-30 16:24
is used for other purposesThe system works fine the vast majority of the time, and is able to transmit
2019-03-26 15:40
我找不到一个发布这个的好地方,但是我有一个安捷伦测试机架,里面装有安捷伦电源和其他东西,后面的所有电缆都很乱。我想清理它,让它看起来更专业。我认为电源的电源线会夹在前后柱上,但似乎没有任何夹子。有没有人有清理那只老鼠的下一根电缆的技巧?您是否将电缆保持在门和柱之间或设备侧面?您是否建议购买“正确”长度的新电源线并摆脱设备附带的长电源线?等等! 以上来自于谷歌翻译 以下为原文I couldn't find a good place to post this, but I have an Agilent test rack with Agilent power supplies and other things stacked up inside and all of the cabling in the back is a mess.I want to clean this up and make it look more professional.I would think that the power cables from the power supplies would clip into the front and rear columns, but there don't seem to be any clips.Does anyone have tricks for cleaning up that rat's next of cables?Do you keep your cables between the door and the column or to the side of the equipment?Do you recommend buying new power cords that are the 'right' length and getting rid of the long ones that came with the equipment? etc. Thanks!
2019-04-24 14:09