• 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
返回

电子发烧友 电子发烧友

  • 全文搜索
    • 全文搜索
    • 标题搜索
  • 全部时间
    • 全部时间
    • 1小时内
    • 1天内
    • 1周内
    • 1个月内
  • 默认排序
    • 默认排序
    • 按时间排序
  • 全部板块
    • 全部板块
大家还在搜
  • ADIS16488A Sensitivity的精度误差怎么更准确

    在ADIS16488A的数据手册中有一个Sensitivity的重复度的最大值,是1%Repeatability1−40°C ≤ TC ≤ +85°C ±1 % 请问,是不是意味着,工厂校准的Sensitivity的精度误差在1%,如果需要更准确的精度,需要每次开机进行手动校准?

    2018-12-11 09:23

  • E8364C PNA的不确定性和跟踪是什么?

    is another word for repeatability. Is this correct? I assume that this is well explained in an app note.Which app note would that be? Thanks Joe

    2018-10-18 17:03

  • 温湿度传感器如何驱动SHT85单片机STM32 HAL库?

    温湿度传感器如何驱动SHT85单片机STM32 HAL库?

    2022-02-07 07:46

  • 请问ADXL355零偏稳定性是多少呢?也就是说常值漂移。

    麻烦帮忙解答,谢谢!

    2018-07-24 06:23

  • 可以使用86100C Infiniium DCA示波器查看用27 GHz载波信号调制的脉冲信号吗

    extremely high accuracy and repeatability with outstanding ease of use to simplify characterizing

    2019-01-14 15:51

  • 请问ADIS16448长期工作时零偏会趋于一个稳定值吗?

    我发现在连续、长期工作状态下,陀螺的零偏会趋于一个稳定值。根据陀螺内部的结构是否能导出这样的结论?这个现象是否有理论支持啊?

    2018-08-20 07:39

  • N4373C:了解测量不确定度的规范和程序

    and also the frequency response repeatability in order to check these specifications

    2018-12-06 16:05

  • 435B-K05输出不确定性

    我的实验室讨论了测量功率计参考输出的问题。我使用432A和478A-H76,或Tegam 1806或1830A以及热敏电阻安装座来测量它们。我的一些同事认为,我们可以通过采用8482A和E4418B以及将435B-K05的输出结果与UUT功率计的参考输出进行比较来准确测量输出。我反对他们的方法的理由是,通过两次测量,不匹配不确定度和仪表误差不确定性将加倍,更不用说必须包括435B-K05输出的不确定性。他们说,由于这是一个相对测量,我们在测量中必须考虑的是435B-K05的输出不确定性。你怎么看?我们需要以这种或那种方式解决这个问题。 以上来自于谷歌翻译 以下为原文There is a discussion at my lab about measuring power meter reference outputs.I measure them using a 432A and a 478A-H76, or a Tegam 1806 or 1830A and a thermistor mount.Some of my associates argue that we could measure the output just as accurately by taking an 8482A and an E4418B and comparing the output results of the 435B-K05 to the UUT power meter's reference output. My reasons against their approach is that by taking two measurements the mismatch uncertainty and instrumentation error uncertainty will double, not to mention the uncertainty of the 435B-K05's output has to be included.They say that since it is a relative measurement all we'd have to consider in the measurement is the 435B-K05's output uncertainty.What do you think?We need to put this issue to rest one way or another.

    2019-08-02 14:33

  • TRL套件的质量

    嗨,我在PCB上制作了一个TRL-kit。不幸的是,sma连接器脚印会降低连接器-cb转换的回波损耗,降低到约。 -15dB。是否有一个关于TRL套件返回损失有多好以便工作的经验法则?我想必须有某种限制? sma连接器内部的线路是50欧姆线。 以上来自于谷歌翻译 以下为原文Hi, I have fabricated a TRL-kit on PCB. Unfortunately, the sma connector foot print degrades the return loss of the connector-pcb transistion down to approx. -15dB. Is there a rule-of-thumb on how good the return loss of a TRL kit need to be in order to work? I guess there has to be some sort of limit? The lines inside the sma connectors are good 50ohm lines.

    2018-11-19 11:03

  • 重复性门控技术为什么测量工作频率为4倍

    mention the technique of gating the connectors of all the standards to see the repeatability

    2018-09-19 16:43