未设置为对象的实例”。如果我单击确定消息窗口程序崩溃。附件在崩溃前显示了一个屏幕转储。有人熟悉这个问题吗?怎么解决?该软件是仪器附带的基础版本3.0。谢谢,Leif 以上来自于谷歌翻译 以下为原文I
2019-04-30 15:05
thought-provoking idea he had seen in ages, yet another (Leif, SM5BZ), who is one of the brightest hams
2019-04-12 15:22
,Leif join_ent_Log_EAP_TLSv1_1Connects.txt.zip 1.2 Kjoin_ent_Log_EAP_TLSv1_2_Fails.txt.zip 1.4 K
2018-11-29 11:51
嗨,我已经下载了一个安捷伦Benchlink构建软件,以便通过USB接口从我的PC到33522A进行通信。我的设备已连接,我可以按照安捷伦交互式I / O发送命令。我在youtube上看过demo但是尽管有说明,我还有一个未指定的错误:对象引用未设置为对象的实例。请在Agilent.Wfe.Gui.SendToInstrDlg.Dispose(布局处理)中将安捷伦技术提供给System.ComponentModel.Component.Finalize(),以便我无法直接发送.arb(附件Double_pulse.arb)文件从构建器软件到33522A。但是,我可以在33522A中根据USB记忆棒加载此文件而不会出现通信问题。这是一个很好的解决方案,但在我的应用程序中,我宁愿直接从构建器向我的仪器发送数据。你能帮我解决一下错误信息和程序吗?最好的祝福 以上来自于谷歌翻译 以下为原文Hi, I have downloaded a Agilent benchlink builder software in order to communicate from my PC to 33522A with USB interface. My device is connected and I can send commands following Agilent interactive I/O. I have seen demo on youtube but in spite of instructions, I have an unspecified error: Object reference not set to an instance of an object. Please provide the information below to Agilent technologies at Agilent.Wfe.Gui.SendToInstrDlg.Dispose(Boolean disposing) at System.ComponentModel.Component.Finalize() So I can't directly send a .arb (attached file Double_pulse.arb) file from the builder software to 33522A. However, I can load this file according to USB stick, in 33522A without communications problems. It's a good solution but in my application I'd rather directly send data to my instrument from the builder. Can you help me about error message and the procedure? Best regards附件Double_pulse.arb36.7 KB
2019-05-28 14:22
在我们的组织中,我们有以下规格NOISE Figure ANALYZER * N8973A(10MHz - 3GHz)NOISE图形分析仪和噪声源是346B(10MHz-18GHz)标称ENR 15dB。*我的问题是,从上面的规范NOISE FIGURE ANALYZE R和噪音来源。我们能够测量0.1 dB或0.2 dB或0.3 dB或0.4 dB甚至小于0.2 dB的噪声系数。因为我们设计了低噪声放大器(LNA),噪声系数为0.2 dB。如果不可能,使用哪个数字NOISE Figure ANALYZER和NOISE SOURCE来测量小于0.2 dB的噪声系数。 以上来自于谷歌翻译 以下为原文In our organization,we have the following specification NOISE FIGURE ANALYSER *N8973A (10MHz - 3GHz) NOISE FIGURE ANALYSER and NOISE SOURCE is 346B (10MHz-18GHz) nominal ENR 15dB.* My question is, from the above specification NOISE FIGURE ANALYSE R and NOISE SOURCE. We are able to measure the 0.1 dB or 0.2 dB or 0.3 dB or 0.4 dB or even less than0.2 dB noise figure. Because We have designed the Low Noise Amplifier (LNA) with 0.2 dB noise figure. If it is not possible, which number NOISE FIGURE ANALYSER and NOISE SOURCE is used for measuring theNoise figure less than 0.2 dB.
2018-11-07 10:02